Filter Results By:

Products

Applications

Manufacturers

Frequency Sources

A stable oscillator used for frequency calibration or reference. (atis.org)


Showing results: 286 - 300 of 311 items found.

  • Miller 400D

    44550 - M. C. Miller Company

    No need to select ranges or adjust dials – the Miller 400D provides a direct read-out of resistance with the push of a button• Bluetooth interface allows optional data-logging via a Bluetooth-enabled PC (or PDA)**• Rugged, hard plastic case - safe to use on wet ground – IP67 rating for dust and water intrusion• Resistance measurement range from 0.01Ω to 10MΩ (auto-ranging) • High resolution digital display• Resistance measurements are unaffected by any stray interference signals that may be present in the earth during readings, due to the use of narrow band-pass filters centered at 82.2Hz (the unit’s operating frequency)• Runs on a set of replaceable D-cell alkaline batteries...no need to periodically recharge the unit or to plug it into a power source• Performs 10,000 single readings on a fresh set of batteries• Integrates with Universal Rectifiers’ Soil Depth Selector/Multi-Pin Cable Harness System (please see Integration with Universal Rectifiers’ Cable Harness)

  • 50Hz-100kHz LCR Meter

    11022/11025 - Chroma Systems Solutions, Inc.

    0.1% basic accuracyTransformer test parameters (11025), Turns Ratio, DCR, Mutual Inductance0Hz, 60Hz, 100Hz, 120Hz, 1kHz, 10kHz, 20kHz, 40kHz, 50kHz, 100kHz test frequencies21ms measurement time (≥100Hz)Agilent 4263B LCR Meter commands compatible4 different output resistance modes selectable for non-linear inductor and capacitor measuringHigh resolution in low impedance(0.01mΩ) and high accuracy 0.3% till 100mΩ rangeAdjustable DC bias current up to 200mA (constant 25Ω) (11025)1320 Bias Current Source directly control capability0.01mΩ ~ 99.99MΩ wide measurement range (4 1/2 digits)Dual frequency function (11022 option) for automatic productionBIAS comparator functionComparator function and 8/99 bin-sorting functionPass/fail judge result for automatic productionHandler interface trigger edge (rising/falling) programmableTest signal level monitor functionStandard RS-232, GPIB, and Handler I/FOpen/short zeroing, load correctionLabView® Driver

  • Electronic Ballast Automatic Test Equipment

    ATE-1 - Lisun Electronics Inc.

    Test series connection, parallel connection and series/parallel connections of the electronic ballast (about 15 kinds of connections), available for various electronic ballast. • With a precise resistance box, tube is substituted for the resistance, can act as many as 6 tubes. Resistance value: 1-4095Ω adjustable. • Measure input parameters (vrms, irms, w, pf, harmonics, etc), output parameters (on-circuit voltage, lamp voltage, filament voltage, lamp current, lamp power, oscillatory frequency), can also test the ballast efficiency, abnormity protection, and power symmetry of partial rectifier effect and etc. • Program controlled AC power source to guarantee the smart choice of input voltage and the frequency. • Equipped with 17 inch LCD controlled machine, specially designed A/D combined with special CPU, has the two left and right testing interfaces to achieve stability of data and high- speed testing. • We can make the special-designed product for you and promise to upgrade the software for free.

  • Near Field Probes 30 MHz up to 6 GHz

    XF1 set - Langer EMV-Technik GmbH

    The XF1 set of near field probes consists of 4 passive near field probes and one passive E field probe for making measurements in the development phase of the magnetic and electric fields in ranges from 30 MHz to 6 GHz. Due to their integrated impendance matching, the probes are less sensitive in the lower frequency range than the RF type probes. The probe heads of the XF1 set allow for the step by step identification of interference sources of the magnetic field on an electronic assembly. At first, for example the XF-R 400-1 detects the fields which the assembly emits in total. Next, using higher resolution probes the interference sources can be more precisely detected. The E field probe is used for the detection of electric interfering fields near the assemblies. With trained use of the near field probes, field orientation and field distribution can be detected. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They have an internal terminating resistance.

  • GPS NTP Time Server - SYNTIME

    Signals & Systems India Private Limited

    Your product description goes hGPS NTP Time Server (SYNTIME) for Network Time Synchronization is a highly accurate time server. It generates time protocols to synchronize NTP/SNTP clients (Simple Network Time Protocol)/PTP clients (Precision time protocol IEEE 1588) over the network and operates at a speed of 10/100/1000Mbps. The NTP server accepts the time and frequency signals from sources like GPS or GLONASS. It achieves nanosecond accuracy and the system clock operates at stratum 1 when synchronized with time sources. It is a sleek, rack-mountable unit that synchronizes and maintains equipment/device time and avoiding any time drifts due to local RTCs. NTP output from time server supports unicast, broadcast, and multicast methods based on selection and behaves like a reference clock for the network. Apart from time synchronization protocols, it supports MD5 (Security key), SNMP, SSH, HTTP (Configuration), TELNET, FTP, and SYSLOG. IP address of the LAN ports can be field configurable.

  • 300KHz Precision LCR Meter

    Model 4300R - Aplab Limited

    Aplab Precision LCR Meter Model 4300R is a new generation of impedance test equipment with high accuracy, wide measurement range and six digits resolution. Being featured with test frequency up to 300kHz, test voltage of 5mV ~ 2V, built-in -5V ~ 5V DC bias and -10V~10V DC voltage source output, it can meet all requirements for measuring components and materials and provide guarantees for production line quality assurance, incoming inspection and laboratory precision measurements. The Handler, RS232C and GPIB interfaces as well as improved command system provided by the instrument make it easier to build the test system.

  • Function Generators

    Shanghai MCP Corp

    Respective dual channels function/arbitrary waveform generator. Sine wave output up to 160MHz, full-band resolution of 1μHz. Pulse waveform up to 50MHz (or 40MHz), adjustable time of rising, falling and duty ratio. Sampling rate of 500MSa/s and vertical resolution of 16bit. 6-bit high-precision frequency meter compatible with TTL level signal. Arbitrary wave storage of 8~32M points, 7GB non-volatile waveform storage. Multi modulation function::AM,FM,PM, ASK,FSK,PSK, BPSK, QPSK,OSK,PWM, QAM, SUM . 16bit digital arbitrary wave (TTL level) DARB. 16th Harmonic Generation Function. Protocol output: I2C, SPI, UART (TTL level). 8 Inch high-resolution TFT color LCD,WVGA(800×480). Standard interface: USB Host, USB Device, LAN, 10MHz clock source input/output. Frequency sweep and burst output. Easy-to-use multi-functional knob and numeric keypad

  • Near Field Probes 1GHz - 10 GHz

    SX set - Langer EMV-Technik GmbH

    The SX1 set consists of 3 passive near field probes for making measurements in the development phase of E-field and magnetic field with a high clock frequency in the range from 1 GHz to 10 GHz. The probe heads of the set SX allow for measurements close to electronic assemblies, e.g. on single IC pins, conducting paths, components and their connectors, to localize interference sources. Field orientation and field distribution on an electronic assembly can be detected through trained use of the near field probe. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They have an internal terminating resistance.

  • Compact Juno USB Interface

    Juno 7Z01250 - mks Ophir

    *Virtual laser power meter - From sensor to interface to PC - no power source needed*Plug and play with all standard Ophir smart sensors*Use with StarViewer free Android app to turn your smartphone / tablet into a power meter*Record every energy pulse at up to 10 KHz*Log power and energy, average, statistics, histograms and more with included StarLab application*New: Pulsed Power measurements with Thermopile sensors*New: Low Frequency Power on Photodiode sensors - power measurement based on pulse cycle (for VCSEL)*System Integrator Tools included: LabVIEW VIs, COM Object Interface*Very compact - is just an extension of the smart plug

  • Radio Test Set

    CMA180 - Rohde & Schwarz GmbH & Co. KG

    With its frequency range from 100 kHz to 3 GHz, the R&S®CMA180 is ideal for testing all common analog and digital radio systems. Input levels up to 150 W are no problem for the R&S®CMA180. The flexible internal switching capabilities for the audio and RF paths make the R&S®CMA180 suitable for a wide range of test requirements. Users can configure the internal generators, external audio sources, filters and measurements according to the given application. In the predefined test scenarios for receiver, transmitter and duplex tests, the RF and audio paths are preconfigured. This saves time and eliminates configuration errors for standard test cases.

  • Scanner Probe

    RFS set - Langer EMV-Technik GmbH

    The RFS set consits of three passive near field probes designed for the use in a measurement scanner during the development of E-field and magnetic field. They are designed for frequency ranges of 30 MHz to 3 GHz. The probe heads of the RFS set allow for close measurements needed to correctly localize interference sources on an electronic assembly. They document the whole image of the device under test`s near field. The scanner probes have a sheath current attenuation and are electrically shielded. They are connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance. The measuring signal can be increased with PA 203 or PA 303 preamplifier. On request RFS, LFS and XFS scanner probes can be produced.

  • Digital Multimeter and Phase Rotation Tester

    3000 MPR - Standard Electric Works Co., Ltd

    ● 4000-count LCD● Auto ranging● Voltage, Resistance, Current, Continuity, Diode measurement● Can measure Resistance up to 200.0 Mohm● Checks a wide range of 3-phase power sources (80~750VAC)● Phase Rotation indication : clockwise and counter-clockwise on LCD● The LCD will show AC voltage between phases and Phase Rotation● Wide range for capacitance test: 0~40000μF(40.00mF)● REL / Auto-Zero function● MAX /MIN function● VAHz function● Frequency : 40.00 MHz● Data hold function● Over range indication● Low battery detection● Auto power off in 15 minutes● Convenient stand for viewing● Comply with EN 61010-1, CAT III 600V for the range of 600V AC/DC

  • Ettus USRP X410, 1 MHz to 7.2 GHz, 400 MHz Bandwidth, GPS-Disciplined OCXO, USRP Software Defined Radio Device

    787272-01 - NI

    The Ettus USRP X410 integrates hardware and software to help you prototype high-performance wireless systems and perform over-the-air signal generation and analysis. Additionally, the Ettus USRP X410 features a two-stage superheterodyne architecture with four independent transmitter and receiver channels. It also features a Xilinx Zynq Ultrascale+ RFSoC with programmable FPGA supporting the Open Source UHD tool flow as well as LabVIEW FPGA. With these features, the Ettus USRP X410 has the RF and processing performance for applications such as wireless communications prototyping, spectrum monitoring, and signals intelligence. The Ettus USRP X410 is equipped with a GPS-disciplined 10 MHz oven-controlled crystal oscillator (OCXO) Reference Clock, which improves frequency accuracy and synchronization.

  • 1μΩ-4kΩ AC Milliohmmeter Low Resistance Tester

    TH2521 - Shenzhen Chuangxin Instruments Co., Ltd.

    TH2521 AC Milliohmmeter is a high-performance and intelligent tester widely used to test contact resistance, internal resistance and battery voltage. The application of constant current source with 1kHz frequency can greatly eliminate the potential error caused by thermoelectricity on DUT. This meter has the function to automatically detect contact failures on test cable. At the range of 30mΩ, basic R resolution can reach 1μΩ. It is applicable for transformer, inductance coil copper resistance, relay contact resistance, switch, connector contact resistance, wire resistance, PCB line and via reistance dan metal defect detection, etc. In the mean time, signals, such as HIGH, LOW, PASS, can be output through HANDLER interface, thus it is very convenient to be used in automatic production line.

  • Compact Antenna Test Range

    700.00 MHZ – 110000.00 MHZ - MVG

    A Compact Antenna Test Range (CATR) allows electrically large antennas to be measured at a significantly shorter distance than would be necessary in a traditional far-field test range. Compact ranges use a source antenna (feed) to radiate a spherical wave in the direction of a parabolic reflector, collimating it into a planar wave for aperture illumination of a Device under Test (DUT). It's lowest operational frequency is determined by the size of the reflector, its edge treatment and the absorbers. The two edge treatments available are serrated edge for general purpose applications, and rolled edge to achieve higher accuracy for special applications. Multiple-feed systems may be used to improve the far-field characteristics. A compact range test system also allows system level testing of a complete device architecture.

Get Help